We take zero commissions. No facility pays us for placement, referrals, or your booking — unlike lead-gen sites.
← All communities
Memory care

Clinton Place

0.00 reviews · 0 verifiedClinton, KYLic. 185469
Signals
FINECMS fine: $8,512Source: CMS Penalties
Photos
Provided by facility
About

Clinton Place Rehabilitation offers a compassionate and holistic approach to healthcare, located in Hickman County, near Columbus, KY. The facility provides personalized attention and a home-like atmosphere, ensuring comprehensive care tailored to each resident's needs. With a dedicated staff and clinical support from medical professionals, residents receive quality care in a nurturing environment. The facility emphasizes joyful experiences and positive interactions, making it a trusted choice for families seeking care for their loved ones.

Amenities
Safety & SecuritySecured Memory Care Unit
CMS Care CompareView on Medicare.gov →
Medicare overall
2/5Medicare.gov Care Compare stars are shown for context only. They are never part of the Unbeatable composite score.
Staffing (PBJ)
3.04 total HPRDRN 0.61 · weekend 85%Oct 2025 – Dec 2025
Survey history
6 inspections34 deficiencies on record
Federal IDs
CCN 185469

Overall: 2/5 · Health: 3/5 · Staffing: 2/5 · QM: 1/5

Unbeatable ratings come only from verified family, staff, and professional reviews on this site. CMS stars, staffing, and citations are public regulatory signals — useful for context, not blended into our score.

Recent inspections
Health surveyAug 2025 · CMS4 deficiencies
  • F-550SS DHonor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.
  • F-761SS DEnsure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.
  • F-812SS DProcure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
  • F-919SS DMake sure that a working call system is available in each resident's bathroom and bathing area.
Fire safetyAug 2025 · STATE FIRE MARSHAL8 deficiencies
  • K-222SS DAdd doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.
  • K-293SS DHave properly located and lighted "Exit" signs.
  • K-321SS EEnsure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
  • K-324SS DProvide properly protected cooking facilities.
  • K-363SS EInstall corridor and hallway doors that block smoke.
  • K-372SS EEnsure smoke barriers are constructed to a 1 hour fire resistance rating.
  • K-500SS EMeet other general requirements that are deficient.
  • K-923SS DHave proper medical gas storage and administration areas.
Health surveyJun 2024 · CMS2 deficiencies
  • F-684SS GProvide appropriate treatment and care according to orders, resident’s preferences and goals.
  • F-925SS FMake sure there is a pest control program to prevent/deal with mice, insects, or other pests.
Fire safetyJun 2024 · STATE FIRE MARSHAL9 deficiencies
  • K-211SS EKeep aisles, corridors, and exits free of obstruction in case of emergency.
  • K-321SS EEnsure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
  • K-345SS FHave approved installation, maintenance and testing program for fire alarm systems.
  • K-355SS DProperly select, install, inspect, or maintain portable fire extinguishes.
  • K-372SS FEnsure smoke barriers are constructed to a 1 hour fire resistance rating.
  • K-912SS EHave power receptacles that are properly grounded.
  • K-918SS FHave generator or other power source capable of supplying service within 10 seconds.
  • K-920SS DEnsure proper usage of power strips and extension cords.
  • K-921SS FEnsure that testing and maintenance of electrical equipment is performed.
Health surveyMar 2019 · CMS8 deficiencies
  • F-580SS DImmediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.) that affect the resident.
  • F-637SS DAssess the resident when there is a significant change in condition
  • F-656SS DDevelop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.
  • F-657SS DDevelop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals.
  • F-690SS DProvide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.
  • F-698SS DProvide safe, appropriate dialysis care/services for a resident who requires such services.
  • F-761SS DEnsure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.
  • F-812SS FProcure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
Fire safetyMar 2019 · STATE FIRE MARSHAL3 deficiencies
  • K-291SS FInstall emergency lighting that can last at least 1 1/2 hours.
  • K-324SS DProvide properly protected cooking facilities.
  • K-905SS EEnsure that gas containers are correctly designed and tested, and in locations that are labeled.
Reviews

No reviews from this reviewer type yet.

Questions & answers

No questions yet. Ask the first one — a member of our team or someone who knows this community will answer.

Have a question about this community?

Ask anything — pricing, care, staffing, daily life. Our team answers, and questions are reviewed before they appear.
Your name and email are used only to follow up — they are never shown on the public question.
Ownership

Operated by SIMCHA HYMAN & NAFTALI ZANZIPER (privately held) since 2012.

  1. Dec 2021
    operator transition — VUJANOVIC, MICK
    INDIRECT OWNERSHIP INTEREST (NOT APPLICABLE) — VUJANOVIC, MICK
Contact

106 Padgett drive
Clinton, KY 42031

2706535558clinton-place.com
Write a review